📞 +91 98122 41001 ✉ info@kelvinindia.in 💬 WhatsApp
NSICMSMEISO 9001/14001/45001BISGeM-OEMCSIR-CMERIZED Pledged
Medical Waste Incinerator (MWI)

BMWM 2016-compliant Medical Waste Incinerator for hospitals & ULBs.

Double-chamber pyrolytic combustion incinerator engineered for yellow-bag biomedical waste under BMWM 2016. Capacities 25 / 50 / 100 / 200 kg/hr. GeM-Verified OEM under product code 90131500.

25–200 kg/hrCapacity range
≥ 1050 °CSecondary chamber
≥ 1 secDwell time
BMWM 2016CPCB-aligned design
SECONDARY ≥ 1050 °C PRIMARY 850 °C BURNER CHARGING DOOR ASH KWTPL · MWI BMWM-2016
Capacity ladder

One platform, four standard capacities

Custom capacities up to 500 kg/hr engineered against site DPR.

ModelCapacityBest forIndicative CapEx (ex-Manesar, 2026)
MWI-2525 kg / hrClinic, nursing home, small private hospital~₹9.5 – 13 L
MWI-5050 kg / hrDistrict hospital, mid-size institution~₹14 – 18 L
MWI-100100 kg / hrMid-tier hospital, hospital cluster~₹20 – 28 L
MWI-200200 kg / hrLarge hospital, CBWTF (common bio-medical waste treatment facility)~₹30 – 35 L

Excludes: CPCB-mandated air pollution control system (APCS — wet scrubber + cyclone + bag filter), site civil work, foundation, stack height as per site authority, CTE/CTO consent fees. KWTPL provides design documentation; the buyer secures consents.

Engineering

Built to BMWM 2016 & CPCB norms

🔥Combustion design

  • Primary chamber: 800–950 °C, refractory-lined
  • Secondary chamber: ≥ 1050 °C, dwell time ≥ 1 second
  • Forced-draft air supply with combustion air pre-heater
  • LDO / diesel fuel; LPG / NG dual-fuel option Optional

🏛Compliance & documentation

  • BMWM 2016 — Bio-Medical Waste Management Rules
  • CPCB emission norms aligned (PM, HCl, CO, dioxin/furan)
  • Design documentation pack for CTE / CTO application
  • Stack design per state pollution control board requirements

🛡Safety architecture

  • Auto burner-cut on door open
  • Over-temperature interlock + alarm
  • Refractory wall thermal insulation — outer skin < 60 °C
  • Pneumatic ash extraction Optional

Controls & automation

  • PLC-controlled burner sequencing & air dampers
  • HMI touchscreen with batch logs & alarm history
  • SCADA + remote monitoring Optional
  • Online stack analyser hookup point Optional
Buyer profile

Who buys a KWTPL MWI?

🏥 Hospitals & nursing homes

Self-treatment of yellow-bag waste under BMWM 2016 — typical 25–50 kg/hr units for clinics and district hospitals; 100 kg/hr for mid-tier multi-specialty.

🏛 ULBs & municipal CBWTFs

Common Bio-Medical Waste Treatment Facilities serving multiple healthcare providers — typical 100–200 kg/hr capacity, often clustered with K-Civic MSWM lines.

🏗 EPC & consulting partners

PSU and Smart City consultants specifying BMWM 2016 compliance into integrated waste-management contracts. KWTPL supplies BOQ-ready spec sheets & design dossiers.

FAQ

Common questions

Is the MWI compliant with BMWM 2016 and CPCB norms?

Yes. Our Medical Waste Incinerator is designed to align with the Bio-Medical Waste Management Rules 2016 (BMWM 2016) and CPCB emission norms — double-chamber pyrolytic combustion, secondary chamber dwell time ≥ 1 second at ≥ 1050 °C, refractory lining, scrubber system. The buyer is responsible for obtaining CPCB consent-to-establish (CTE) and consent-to-operate (CTO) at the installation site; KWTPL provides design documentation to support the application.

What capacities are available?

Standard: 25 / 50 / 100 / 200 kg/hr. Custom up to 500 kg/hr engineered against site DPR.

Which waste streams does it handle?

Yellow bag waste under BMWM 2016 — anatomical, soiled, infectious, expired pharma, chemical wastes. Not designed for radioactive, mercury, or pressurized container waste. Feedstock matrix provided during DPR review.

What's the indicative CapEx?

Ex-Manesar (2026): 25 kg/hr ~₹9.5–13 L · 50 kg/hr ~₹14–18 L · 100 kg/hr ~₹20–28 L · 200 kg/hr ~₹30–35 L. Add APCS (wet scrubber + cyclone + bag filter), refractory upgrade, PLC + SCADA, civil work as accessories. Use the configurator for a tailored estimate.

Is KWTPL a verified OEM for MWI?

Yes. KWTPL is a GeM-Verified OEM for Medical Waste Incinerator under GeM product code 90131500. Visit gem.gov.in to view the public listing, or browse our full credentials & compliance page.

Lead time and AMC?

Manufacturing lead time 8–12 weeks ex-Manesar depending on capacity and APCS scope. Comprehensive 1-year warranty + AMC packages from year 2. Engineer on-site within 24–48 hours of any service call.

Lead time & service SLA

Manufactured to dispatch in 6–14 weeks

Standard configurations from stock-cycle production; custom builds against site DPR. Every machine ships with 1-year warranty + AMC option from year 2.

6–14 wkManufacturing lead time
1-yearComprehensive warranty
24–48 hrEngineer on-site SLA
Same daySpare parts ex-Manesar

Need a BMWM 2016-compliant MWI for your site?

Tell us hospital size, daily yellow-bag volume and target capacity — we'll send a tailored brief, BOQ-ready spec sheet and design documentation pack for your CTE/CTO application.

Configure your enquiry → Email engineering